First installation: single-cable system (manual) – Kathrein UFS 902 User Manual

Page 24

Advertising
background image

24

Selection “UAS 481” or “EXR 551”

Transmission channel

Use the



buttons to select a free available transmission channel. A maximum of four transmission

channels are available (1400, 1516, 1632 and 1748 MHz).

Test connection

When you have set a free transmission channel, press the



buttons to switch to the “Test

connection” selection fi eld and press the



button. The receiver now tests whether a connection to the

single-cable system can be established or not. As soon as the receiver has established a connection to
the single-cable system, you will see the following display:

FIRST INSTALLATION: Single-cable system (manual)

When the UAS 481 single-cable
feed system is being used, it is
essential that the LNB is set to
“Wideband”!
When the EXR 551 single-cable
switching matrix is being used, it
is essential that the LNB is set to
“Universal”!

If no connection to the single-cable system could be established, the following display appears:

Check your settings and if necessary call for expert help.

Press the



button to acknowledge this display.

Then press the



button. You will be asked whether you

wish to save the changes. Use the



buttons to select

“Yes, save changes” and confi rm by pressing the



button. Now press the

!

(green) button.

The receiver will automatically display the menu for the
channel search. Continue with the section (Execute channel
search).