Configuration in the ai296 local menu system – Kentrox AI296 User Manual
Page 103

AI296 Version 9.8x User’s Guide
Link Configuration: BX.25 Configuration
6-9
This example displays
05 Connect Timer ST2
set to
33
and
06 Send Timer ST3
set to
45
.
Configuration in the AI296 Local Menu System
1. Access the X.25 Link Menu.
2. From the X.25 Link Menu, select the
BX.25 Menu
.
3. For
Connect Timer ST2
, enter the connect timer value. The default is
12
.
4. For
Send Timer ST3
, enter the send timer value. The default is
18
.
This example displays
Connect Timer ST2
set to
225
and
Send Timer ST3
set to
275
.
>6,35
Menu 4.2.11.12.11
01*BX25 Support (Enabled, Disabled)------------------------------------ Enabled
02*Use these configuration values (Enabled, Disabled)------------------ Enabled
03 Sending Unit Number (0 - 9)------------------------------------------------2
04 Modulo (5 - 256)---------------------------------------------------------122
05 Connect Timer ST2 (seconds)--------------------------------------------00033
06 Send Timer ST3 (seconds)-----------------------------------------------00045
BX.25 Menu
Link being configured . . . . . . . . . . . . . . . . . . . . . . . . . 03
BX.25 Support . . . . . . . . . . . . . . . . . . . . [Enabled] Disabled
Use BX.25 Configuration Values. . . . . . . . . . . . [Enabled] Disabled
Sending Unit Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
BX.25 Modulo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200
Connect Timer ST2 (seconds) . . . . . . . . . . . . . . . . . . . . . . .. 225
Send Timer ST3 (seconds). . . . . . . . . . . . . . . . . . . . . . . . .. 275