Standalone mode refers to the mode where AI296 stores its configuration locally (to
flash) or on a TFTP server. The CLC might be used as the TFTP server in some
cases. This lets the card operate as a self-contained unit. When operating in
standalone mode, AI296 has a local menu system that is used instead of the AI198
menu system for tasks such as alias and IP configuration. AI296 operates in
standalone mode when it is installed in the AI110 chassis.

The following characteristics apply when AI296 is operating in standalone mode:

z

The front panel Ethernet port is the default (rather than the IRB).

z

AI296 cards are not hot-swappable—the card configuration must be set up
manually.

z

AI296 has a unique system OID.

z

The AI296 local menu system has slightly different options than when the card is
running in switch mode.

Downloading Software for a Standalone AI296

To download software for AI296 in standalone mode:

1. Open a command prompt window.

2. At the command prompt, start the FTP utility:

ftp

3. At the FTP prompt, open AI296:

open

ip_address

The FTP utility prompts you for a user name and password.

4. Put the FTP utility in binary mode:

binary

5. Transfer the software image to AI296:

put

filepath

/

imagename

.img



Note: Wait for a completion message after entering this command.

ip_address

Specifies the AI296 IP address.

filepath

Defines the path to the software image file.

imagename

Defines the software image file name.