Passive link with clocking, Passive link with clocking -33 – Kentrox AI296 User Manual

Page 127

Advertising
background image

AI296 Version 9.8x User’s Guide

Link Configuration: General Link Properties Configuration

6-33

Passive Link with Clocking

Description

This menu item enables or disables an X.25 passive link from supplying a clock value
while the link is in the inactive state.



Note: Old AT&T 5ESS interface cards (TN983) require clocking with the passive link

set up.

Menu Item Type

Toggle

Link Type Availability

X.25

Configuration in the AI198 Menu System

1. Access Menu 4.2.11.12.

2. For

13*Passive Link with Clocking

, enter

13

to select

Enabled

or

Disabled

. The

default is

Disabled

.

This example displays

13*Passive Link with Clocking

set to

Enabled

.

Configuration in the AI296 Local Menu System

1. Access the X.25 Link Menu.

2. From the X.25 Link Menu, select

Quick X.25 Menu

. The Quick X.25 Menu appears.

3. For

Passive Link with Clocking

, select

Enabled

or

Disabled

. The default is

Disabled

.

>13
Menu 4.2.11.12
01 Link number (1-16)--------------------------------------------------------05
02*Link Type (Async, X25, HDLC, SyncPPP, AsyncPPP, MLT)---------------- X.25
03 Link Description------------------------------ X.25 link 5
04*Link state (Enabled, Disabled)--------------------------------------Disabled
05*Link mode (Normal, Passive, Extended)------------------------------- Normal
06 Port speed (0 - 128000 bps, 0 is external clocking)-------------------009600
07+X25 LAPB Parameters
08+X25 Parameters
09+Virtual Circuits
10*Hardware Interface (RS232,RS530,V.35)----------------------------------RS232
11+BX25 Configuration
12 Auto Disable Error Limit (0-1000000)---------------------------------0000000
13*Passive Link with Clocking (Enabled, Disabled)---------------------- Enabled