Lapb timer settings, Lapb timer settings -49 – Kentrox AI296 User Manual
Page 143

AI296 Version 9.8x User’s Guide
Link Configuration: LAPB Parameters Configuration
6-49
Menu Item Type
Toggle
Link Type Availability
MLT and X.25
Configuration in the AI198 Menu System
1. Access menu 4.2.11.12.7 for MLT or menu 4.2.11.12.8 for X.25.
2. For
01*Interface mode
, enter
1
to select
DCE
or
DTE
. The default is
DCE
.
This example displays
01*Interface mode
set to
DTE
.
LAPB Timer Settings
Description
The LAPB timer settings are configured using three menu items:
z
T1 ack timer
—Defines the maximum amount of time from the end of transmission
to the receipt of an acknowledgment.
z
T2 ack delay timer
—Defines the time available from the receipt of a frame until a
response has to be transmitted.
z
T4 idle timer
—Defines the maximum time allowed without the exchange of
frames on a data link.
Menu Item Type
Data
Link Type Availability
MLT and X.25
Configuration in the AI198 Menu System
1. Access menu 4.2.11.12.7 for MLT or menu 4.2.11.12.8 for X.25.
2. For
05 T1 ack timer
, enter
5,
and the timer value. The default is
3000
.
3. For
06 T2 ack delay timer
, enter
6,
and the timer value. The default is
4000
.
4. For
07 T4 idle timer
, enter
7,
and the timer value. The default is
25000
.
>1
Menu 4.2.11.12.8
01*Interface mode (DTE or DCE)----------------------------------------------DTE