AI296 Version 9.8x User’s Guide

Link Configuration: X.25 Parameters Configuration

6-81

This example displays

01*X25 Facilities negotiation

set to

ON

.

Configuration in the AI296 Local Menu System

1. Access the X.25 Link Menu.

2. Select

X.25 Parameters Menu

. The X.25 Parameters Menu appears.

3. For

X25 Facilities Negotiation

, select

Enabled

or

Disabled

. The default is

Disabled

.

This example displays

X25 Facilities Negotiation

set to

Enabled

.

X.25 Timer Settings

Description

The X.25 timer settings are configured using eight menu items:

z

T20 restart timer

—Defines the amount of time allowed for receipt of a restart

confirmation or restart indication after a restart request.

z

T21 call timer

—Defines the amount of time allowed for receipt of call connected,

clear indication, or incoming after a call request.

z

T22 reset timer

—Defines the amount of time allowed for receipt of a reset

confirmation or reset indication after a reset request.

z

T23 clear timer

—Defines the amount of time allowed for receipt of a clear

confirmation or clear indication after a restart request.

z

T24 window timer

—Defines the amount of time allowed for window status

transmission.

z

T25 data retransmission timer

—Defines the amount of time allowed for T25 data

retransmission.

z

T26 interrupt timer

—Defines the amount of time allowed for receipt of an interrupt

confirmation after an interrupt is sent.

z

T28 registration timer

—Defines the amount of time allowed for receipt of a

registration confirmation after a registration request.

>1
Menu 4.2.11.12.8
01*X25 Facilities negotiation----------------------------------------------- ON

X.25 Parameters Menu

Link being configured . . . . . . . . . . . . . . . . . . . . . . . . . 03

X25 Facilities Negotiation . . . . . . . . . . . . . [Enabled] Disabled