background image

Maintenance Port Antenna Commands

54-0198

135

Set RF Tracking Parameters

Function:

sets RF tracking parameter

Command:

@SATCONFIG,X,N,F,S,C,ID,P,B,D<cr>

Response:

Echoes the input data

Where:

@SATCONFIG = directs data to the RF Board

X = satellite A or B

N = satellite table # (98 & 99 are slots for user-

configured satellites)

F = frequency in MHz (either 00000 or a range from

10700 - 12700)

S = the satellite transponder symbol rate in

Mbit/second (01000 - 29999)

C = the FEC code (e.g., 12, 23, 34, 56, 67, 78)

ID = the satellite network ID in hexidecimal format

(0x####)

P = the LNB polarization (V = vertical,

H = horizontal, R = right, L = left)

B = the LNB down conversion frequency (L = low,

H = high, G = Latin America, U = USA)

D = decoding type (1 = DSS-A, 2 = DSS-B,

3 = DVB)

ID Match/Decoded Network ID

Function:

report ID match and decoded network ID

Command:

@CHECKID

Response:

one of the following:
Y,0X####
N,0X####
Y,NoID
N,NoID
N,NoLock

Where:

Y = yes
N = no
0X#### = network ID
NoID = satellite unidentified
NoLock = satellite not found