LG C Series User Manual

Page 60

Advertising
background image

Chapter 9. Basic functions


CHAPTER 9 -

Basic Functions

9.1

Frequency mode

z Digital Frequency setting via Keypad 1

Group

LED Display

Parameter Name

Set

Value

Min/Max

Range

Factory

Defaults

Unit

0.0 [Frequency

Command] - 0/400

0.0 Hz

Drive
group

Frq

[Frequency mode]

0

0/8 0

ƒ Run frequency is settable in 0.0 - [Frequency Command].
ƒ Set

Frq – [Frequency mode] to 0 {Frequency setting via Keypad 1}.

ƒ Set the desired frequency in 0.0 and press the Prog/Ent (z) key to enter the value into memory.
ƒ The value is settable not greater than F21 – [Max frequency].

z Digital Frequency setting via Keypad 2

Group

LED Display

Parameter Name

Set

Value

Min/Max

Range

Factory

Defaults

Unit

0.0 [Frequency

Command] - 0/400

0.0 Hz

Drive
group

Frq

[Frequency mode]

1

0/8 0

ƒ Run frequency is settable in 0.0 - [Frequency Command].
ƒ Set

Frq – [Frequency mode] to 1{Frequency setting via Keypad 2}.

ƒ In

0.0, frequency is changed upon pressing the Up (

S)/Down (T) key. It is selected to use the

Up/Down key as potentiometer on keypad.

ƒ The value is settable not greater than F21 – [Max frequency].

60

Advertising