10. Advanced

functions

10.1 DC brake

z Stop mode via DC brake

Group

LED Display

Parameter Name

Set

value

Min/Max

Range

Factory

Defaults

Unit

F 4

[Stop mode select]

1

0/2 0

F 8

[DC Brake start
frequency]

- 0/60 5.0

Hz

F 9

[DC Brake wait time]

- 0/60 0.1

sec

F10

[DC Brake voltage]

- 0/200 50 %

Function
group 1

F11

[DC Brake time]

- 0/60 1.0

sec

ƒ Set F4 - [Stop mode select] to 1.
ƒ F 8: The frequency at which the DC brake will become active.
ƒ F 9: Inverter will wait for this time after F8 - [DC Brake start frequency] before applying F10 - [DC

Brake voltage].

ƒ F10: It sets the level as a percent of H33 – [Motor rated current].
ƒ F11: It sets the time that F10 - [DC Brake voltage] is applied to the motor after F 9 - [DC Brake wait

time].

CAUTION:
If excessive DC Brake voltage is set or DC Brake time is set too long, it may cause motor
overheating and damage to the motor.

Freq.

Run
command

Voltage

Current

F 8

F9

F11

F10



Setting F10 or F11 to 0 will disable DC brake.



F 9 – [DC Brake Wait time]: When load inertia is great or F 8 – [DC Brake Start

Frequency] is high, Overcurrent trip may occur. It can be prevented via F9.