10. Advanced functions

z Parameter

Lock

Group

LED

Display

Parameter Name

Set

value

Min/Max

Range

Factory

Defaults

Unit

H95

[Parameter lock]

-

0/FFF

0

Function
group 2

H94

[Password Register]

-

0/FFF

0

ƒ This parameter is used to lock the user-set parameters using the password.



See the table below to lock the user-set parameter via the H94 – [Password Register].

Step Description

LED

Display

1

Go to H95 – [Parameter lock]

H95

2

Enter the Prog/Ent (

z) key

UL

3

Parameter value can be changed in UL (Unlock) status.
While seeing this message…

UL

4

Enter the Prog/Ent (

z) key.

0

5

Enter the password created in H94 (e.g.: 123).

123

6

Enter the Prog/Ent (

z) key

L

7

Parameter value cannot be changed in L (Lock) status.

L

8

Press either the left (

W) or right (X) key.

H95



See the table below to unlock the user-set parameter via password.

Step Description

LED

Display

1

Go to H94 – [Password register]

H94

2

Press the Prog/Ent (

z) key

L

3

Parameter value cannot be changed in L(Lock) status.

L

4

Press the Prog/Ent (

z) key

0

5

Enter the password created in H94 (e.g.: 123).

123

6

Press the Prog/Ent (

z) key

UL

7

Parameter value can be changed in UL (Unlock) status.
While seeing this message…

UL

8

Press the Prog/Ent (

z) key

H95

98