10. Advanced functions
z Parameter
Lock
Group
LED
Display
Parameter Name
Set
value
Min/Max
Range
Factory
Defaults
Unit
H95
[Parameter lock]
-
0/FFF
0
Function
group 2
H94
[Password Register]
-
0/FFF
0
This parameter is used to lock the user-set parameters using the password.
See the table below to lock the user-set parameter via the H94 – [Password Register].
Step Description
LED
Display
1
Go to H95 – [Parameter lock]
H95
2
Enter the Prog/Ent (
z) key
UL
3
Parameter value can be changed in UL (Unlock) status.
While seeing this message…
UL
4
Enter the Prog/Ent (
z) key.
0
5
Enter the password created in H94 (e.g.: 123).
123
6
Enter the Prog/Ent (
z) key
L
7
Parameter value cannot be changed in L (Lock) status.
L
8
Press either the left (
W) or right (X) key.
H95
See the table below to unlock the user-set parameter via password.
Step Description
LED
Display
1
Go to H94 – [Password register]
H94
2
Press the Prog/Ent (
z) key
L
3
Parameter value cannot be changed in L(Lock) status.
L
4
Press the Prog/Ent (
z) key
0
5
Enter the password created in H94 (e.g.: 123).
123
6
Press the Prog/Ent (
z) key
UL
7
Parameter value can be changed in UL (Unlock) status.
While seeing this message…
UL
8
Press the Prog/Ent (
z) key
H95