10. Advanced functions

10.13 Carrier frequency select

Group

LED Display

Parameter Name

Set

value

Min/Max

Range

Factory

Defaults

Unit

Function
group 2

H39

[Carrier frequency
select]

-

0/15 10

ƒ This parameter affects the sound of the inverter during operation.

Motor noise

v

Heat loss of the inverter

u

Inverter noise

u

H39

If carrier frequency set

higher

Leakage current

u

10.14 Second motor operation

Group

LED Display

Parameter Name

Set

value

Min/Max

Range

Factory

Defaults

Unit

H81

[2

nd

motor Accel time]

- 0/6000 5.0 Sec

H82

[2

nd

motor Decel time]

- 10.0

Sec

H83

[2

nd

motor base

frequency]

- 30/400 60.0 Hz

H84

[2

nd

motor V/F pattern]

- 0/2 0

H85

[2

nd

motor forward torque

boost]

- 0/15 5 %

H86

[2

nd

motor reverse torque

boost]

- 5

%

H87

[2

nd

motor stall prevention

level]

- 30/200 150 %

H88

[2

nd

motor Electronic

thermal level for 1 min]

- 50/200 150 %

H89

[2

nd

motor Electronic

thermal level for
continuous]

- 100

%

Function
group 2

H90

[2

nd

motor rated current]

- 0.1/20 1.8 A

I20

[Multi-function input
terminal P1 define]

- 0

~ ~

I/O group

I24

[Multi-function input
terminal P5 define]

12

0/24

4

ƒ Select the terminal among Multi-function input P1 thru P5 for second motor operation.
ƒ If using the terminal P5 for second motor operation, set I24 to 12.



Used when an inverter operates 2 motors connected to two different types of the loads.