Chapter 4 Preparing LogTag(s) for use

41

Function

Purpose

Clear and reset alarm
when STOP/CLEAR

button pressed

If this option is enabled, any user can turn off an active alarm by
pressing the LogTag's STOP/CLEAR button. It will also reset the

internal counters such that it would be as if no alarm had occurred

while the LogTag was recording. Should the LogTag subsequently

detect a further alarm condition, the alarm will activate again. Once

the LogTag has finished recording, pressing the STOP/CLEAR

button will not clear and reset any active alarm.
In any case, an alarm will be registered in the day summary,

regardless whether it was cleared or not.

Alarm remains on even
if readings return to

non-violation range

If this option is enabled then the alarm symbol will stay on, even if
the current reading does not meet the alarm conditions specified by

the previous controls.
If this option is disabled then the alarm symbol will stay on only if

the current reading meets the alarm conditions specified by the

previous controls.

Pause alarm/statistics

processing for X

readings

If this option is enabled, pressing either button on the LogTag

while recording excludes the next reading from the alarm and

statistics calculations; PAUSED will now be shown on the display.

This allows the user to review the statistics or clear an alarm
without causing an invalid reading, alarm or statistic.

Switch off display after

30 seconds

If this option is enabled, the display will turn off after 30 seconds to

save battery power.

Allow logging stop with

STOP button

If this option is enabled, the LogTag can be stopped by pressing

the STOP button. The recorder will no longer take any readings,

however you can still review the day statistics and download the
logged results to a PC with LogTag Analyzer.

Allow reset of logger

with START button

If this option is enabled, TRID30-7F and TRID30-7R loggers can be

re-activated and used again for a new trip by pressing the START
button.
When re-activating the recorder, all previously recorded

readings and statistics will be erased!
When this option is enabled, a warning box will be displayed to

remind you this is enabled and can result in loss of data.

Show total summary

days collected

If this option is enabled, the LogTag shows the number of days for

which statistics have already been collected on the display.

Please refer to the

LogTag TRID30-7F product specification & guide

(http://www.logtagrecorders.com/products/pdf/LOGTAG_TRID30-7_PRODUCT_SPECIFIC
ATION.pdf) for a detailed description on the functionality of these products.