Trunk assignments for single-cabinet systems – Philips T-SMART DBS-EX23-530 User Manual

Page 23

Advertising
background image

Installation

Guidelines

Revised April 2000

DBS-EX23-530

2-5

Trunk Assignments for Single-Cabinet Systems

• Programming is not required to associate trunk ports with slot locations.

However, you must use programming to specify that a combination of
ISDN and analog trunks is installed, and you must also specify how many
ISDN channels are used.

• Fractional ISDN per port assignments require the VB-43511A version of

the loop start trunk card. The older VB-43511 version may be used with
fractional ISDN but requires that the trunks be assigned in blocks of 8.

Table 2-2. ISDN and analog trunk assignments, DBS 40

Table 2-3. ISDN and analog trunk assignments, DBS 72

Trunk
Number

Fractional ISDN
using 16 Channels

Fractional ISDN
using 8 Channels

1

ISDN channel 16

Analog trunk 1

8

ISDN channel 9

Analog trunk 8

9

ISDN channel 8

ISDN channel 8

16

ISDN channel 1

ISDN channel 1

Note: Since the DBS 40 supports a maximum of 16 trunks, all 23

channels of the ISDN cannot be used.

Trunk
Number

23-Channel ISDN

Fractional ISDN
using 16 Channels

Fractional ISDN
using 8 Channels

1

Analog trunk 1

Analog trunk 1

Analog trunk 1

2

ISDN channel 23

Analog trunk 2

Analog trunk 2

8

ISDN channel 17

Analog trunk 8

Analog trunk 8

9

ISDN channel 16

ISDN channel 16

Analog trunk 9

16

ISDN channel 9

ISDN channel 9

Analog trunk 16

17

ISDN channel 8

ISDN channel 8

ISDN channel 8

24

ISDN channel 1

ISDN channel 1

ISDN channel 1

Advertising