Installation procedures, Installing the csu – Philips T-SMART DBS-EX23-530 User Manual

Page 30

Advertising
background image

Installation Procedures

Installation

2-12

DBS-EX23-530

Revised April 2000

Installation Procedures

The following procedures provide step-by-step instructions for installing the
CSU and the ISDN Interface. The ISDN procedure that you should use
depends on the type of system you have and the number of ISDNs you are
installing.

Installing the CSU

The following instructions explain how to install the CSU. See “CSU
Equipment” on page 1-9 for spec
ifications on CSUs and CSU cabling.

Note: The CSU can be powered locally or through the CO line. Also, a
locally powered CSU should be connected to an Uninterruptible Power
Supply (UPS) to provide battery backup in case of AC power failures.

1. Connect the equipment cable from the DBS MDF card to the equipment

side of the CSU, as shown in Figure 2-1.

If you’re installing ...

Use this procedure...

A ISDN in a single cabinet

“Installing an ISDN in a Single Cabinet” (page 2-

14)

One ISDN in a double cabinet, with the

ISDN located in the master

“Installing an ISDN in a Single Cabinet” (page 2-

14)

One ISDN in a double cabinets, with the

ISDN located in the slave

“Installing an ISDN in a Double Cabinet with the

ISDN in the Slave” (page 2-21)

ISDNs in both the master and slave

“Installing an ISDN in a Double Cabinet with

ISDNs in the Master and Slave” (page 2-23)