Trunk settings – Philips T-SMART DBS-EX23-530 User Manual

Page 80

Advertising
background image

Trunk Settings

Programming Reference

4-28

DBS-EX23-530

Revised April 2000

Trunk Settings

Parameter

Trunk Type

Description

Determines whether the trunk circuit is an analog loop start, analog
ground start, analog DID, T1, CID, or ISDN.

Note:

For changes to this parameter to take effect, the system

must be powered down, then back up again.

Programming

FF2 (1-64)# 21# (0-5)#

Options

0= Loop start

1=Ground start

2=DID

3=T1

4=CID

5=ISDN

Parameter

ISDN Data Reset

Description

Resets the ISDN settings stored in SRAM (Static Random Access
Memory). The reset restores these settings to default values.

Programming

FF1 9# 1# (0-1)#

Note: If you enter a “1,” the following display appears:

CONFIRM

0: NO 1: YES

The purpose of this display is to make sure you want to reset the
data. Enter a 0 or 1, depending on whether you want to complete
or cancel the reset.

0=Do not reset

1=Reset

Options

0=No (retain settings)

1=Yes (clear settings)