Philips T-SMART DBS-EX23-530 User Manual

Page 75

Advertising
background image

Programming Reference

Alarm Settings

Revised April 2000

DBS-EX23-530

4-23

Parameter

Slip Counter

Description

Determines how many slips occur before a Slip FF key is lit.

The FF key lights when the counter exceeds the specified number
within a 24-hour period.

This parameter also determines the number of slips that can occur
before the system switches to the next clock source. When the sys-
tem switches to the next clock source, the slip error counter for the
first clock source is reset.

Slips are losses of data bits due to framing errors.

(See page 4-35 for instructions on programming FF alarm keys.)

Programming

Master cabinet: FF1 9# 4# 4# 3# 2# (0-9000)#

Slave cabinet: FF1 9# 4# 5# 3# 2# (0-9000)#

Options

0-9000/24 hours

(9000)

Parameter

Red Alarm Counter

Description

Determines how many red alarms occur before a Red Alarm FF
key is lit.

The FF key lights when the counter exceeds the specified number
within a 24-hour period.

(See page 4-35 for instructions on programming FF alarm keys.)

Programming

Master cabinet: FF1 9# 4# 4# 3# 3# (0-9000)#

Slave cabinet: FF1 9# 4# 5# 3# 3# (0-9000)#

Options

0-9000

/

24 hours

(9000)

Advertising