Trunk assignments for double-cabinet systems – Philips T-SMART DBS-EX23-530 User Manual

Page 24

Advertising
background image

Guidelines

Installation

2-6

DBS-EX23-530

Revised April 2000

Table 2-4. ISDN and analog trunk assignments, DBS 96

Trunk Assignments for Double-Cabinet Systems

• When ISDN is used in a two-cabinet system, the number of ISDN channels

that can be assigned in each cabinet depends on the master/slave
designation.

• Fractional ISDN per port assignments require the VB-43511A version of

the loop start trunk card. The older VB-43511 version may be used with
fractional ISDN but requires that the trunks be assigned in blocks of 8.

The following table shows the maximum number of ISDN channels that
can be assigned in two-cabinet systems.

Trunk
Number

23-Channel ISDN

Fractional ISDN
using 16 Channels

Fractional ISDN
using 8 Channels

1

Analog trunk 1

Analog trunk 1

Analog trunk 1

8

Analog trunk 8

Analog trunk 8

Analog trunk 8

9

Analog trunk 9

Analog trunk 9

Analog trunk 9

10

ISDN channel 23

16

ISDN channel 17

Analog trunk 16

Analog trunk 16

17

ISDN channel 16

ISDN channel 16

Analog trunk 17

24

ISDN channel 9

ISDN channel 9

Analog trunk 24

25

ISDN channel 8

ISDN channel 8

ISDN channel 8

32

ISDN channel 1

ISDN channel 1

ISDN channel 1