Special ISDN Function Codes

Programming Reference

4-38

DBS-EX23-530

Revised April 2000

Parameter

Forced Re-synchronization

Description

Re-synchronizes the DBS ISDN with the public network.

Notes:

1. Forced re-synchronization disconnects existing calls.

2. Before executing this code, you must first enter the program-
ming authorization code (#98 9999).

Execution

Master: ON/OFF #94 6

Slave: ON/OFF #95 6

Options

None. Re-synchronization begins as soon as the code is entered.

Parameter

Historical Error Clearance

Description

Clears the error counters for the following alarms:

• yellow
• red
• framing

loss

• slip

rate

• loss of signal
• sync

loss

Note: Before executing this code, you must first enter the pro-
gramming authorization code (#98 9999).

Execution

Master: ON/OFF #94 7

Slave: ON/OFF #95 7

Options

None. The counters are cleared as soon as the code is entered.

Parameter

Alarm Relay Clear

Description

Clears (opens) the alarm relay on the ISDN MDF card.

Note:

Before executing this code, you must first enter the pro-

gramming authorization code (#98 9999).

Execution

Master: ON/OFF #94 8

Slave: ON/OFF #95 8

Options

None. The relay is cleared as soon as the code is entered.