Programming Reference

Special ISDN Function Codes

Revised April 2000

DBS-EX23-530

4-37

Parameter

Remote Loopback

Description

This command only applies to a DBS within a private network.

The command is entered at one DBS in order to loopback through
another DBS.

For example, to initiate a loopback from DBS “B” to DBS “A,”
this command would be entered at DBS “B.” In order for the loop-
back to work, DBS “A” must have the “Remote Loopback” option
turned on in system programming.

Notes:

1. The clock source of the DBS that issues this command must be
set to “free run.”

2. Before executing this command, you must first enter the pro-
gramming authorization code (#98 9999). This command only
applies to a DBS within a private network.

The command is entered at one DBS in order to loopback through
another DBS.

For example, to initiate a loopback from DBS “B” to DBS “A,”
this command would be entered at DBS “B.” In order for the loop-
back to work, DBS “A” must have the “Remote Loopback” option
(page 4-37) turned on in system programming.

Notes:

1. The clock source of the DBS that issues this command must be
set to “free run.”

2. Before executing this command, you must first enter the pro-
gramming authorization code (#98 9999).

Execution

Master: ON/OFF #94 3 (0 or 1)

Slave: ON/OFF #95 3 (0 or 1)

Options

0=Off

1=On

Parameter

AIS Signal Transmission

Description

Transmits an AIS signal (all 1s) to the CO.

Note:

Before executing this code, you must first enter the pro-

gramming authorization code (#98 9999).

Execution

Master: ON/OFF #94 4 (0 or 1)

Slave: ON/OFF #95 4 (0 or 1)

Options

0=Off

1=On