Philips T-SMART DBS-EX23-530 User Manual

Page 60

Advertising
background image

System-Wide Timers

Programming Reference

4-8

DBS-EX23-530

Revised April 2000

Parameter

Ringing Timer (T301)

Description

Determines how long the called party will ring before the DBS will
disconnect the call.

Programming

FF1 9# 4# 2# 2# (0-15)#

Options

0-10

0=180 sec.

1=20 sec.

2=40 sec.

3=60 sec.

.

.

.

11=220 sec.

12=240 sec.

13=240 sec.

14=240 sec.

15=Infinite

Parameter

Call Setup Timer (T303)

Description

Determines the time limit for a CO to respond to an outgoing call
attempt.

Programming

FF1 9# 4# 2# 3# (0-10)#

Options

0-10

0=4 sec.

1=1 sec.

2=2 sec.

3=3 sec.

4=4 sec.

5=5 sec.

6=6 sec.

7=7 sec.

8=8 sec.

9=9 sec.

10=10 sec.