Chapter 2

Setup and Configuration

© National Instruments Corporation

2-9

NI CVS-1450 Series User Manual

Figure 2-2. Basic Hardware Setup

Wiring Power to the CVS-1450 Device

This section describes how to connect the NI desktop power supply.
For instructions on how to connect a separate main supply, refer to the

Connecting to a Separate Main Supply

section.

Caution

Do not connect the CVS-1450 device main power to a source other than

24 VDC ±10%. Do not connect the CVS-1450 device isolated power to a source less than
5 VDC or greater than 30 VDC. Doing so could damage the CVS-1450 device.

To connect power to the CVS-1450 device, refer to Figure 2-3 while
completing the following steps:

1.

Plug the 4-position connector from the power supply into the power
receptacle on the CVS-1450 device.

2.

Plug the power cord into the power supply.

3.

Plug the power cord into an outlet.

The CVS-1450 device ships with a factory-installed startup program that,
when the CVS-1450 device is connected to a camera and powered on,
acquires images and displays them on the monitor. If the images from the
camera display on the monitor, continue to the

Connecting the CVS-1450

Device to the Development Computer

section. If the images from the

1

VGA Cable

2

IEEE 1394 Cable

1

2