Considerations when connecting the digital i/o, Wiring an isolated output to an external load, Considerations when connecting the digital i/o -12 – National Instruments NI CVS-1450 Series User Manual

Page 60

Advertising
background image

Chapter 4

Digital I/O Functionality

NI CVS-1450 Series User Manual

4-12

ni.com

Considerations When Connecting the Digital I/O

The isolated trigger inputs on the CVS-1450 device are current sinking
and optically isolated. Figure 4-6 shows the trigger input interface circuit.

Wiring an Isolated Input to a Sourcing Output Device

You can wire an isolated input to a sourcing output device, as shown in the
example in Figure 4-5. Refer to Appendix B,

Specifications

, for switching

thresholds and current requirements.

Caution

Do not apply a voltage greater than 30 VDC to the isolated inputs. Doing so could

damage CVS-1450 device.

Figure 4-5. Example of Connecting an Isolated Input to a Sourcing Output Device

Wiring an Isolated Output to an External Load

The digital output circuit sources current to external loads, as shown in
the example in Figure 4-6.

Caution

Do not draw more than 100 mA from 24 V or 30 V isolated outputs. Do not draw

more than 50 mA from 5 V isolated outputs.

Vcc

Sourcing

Output
Device

Viso

Current

Limiter

Ciso

CVS-1450 device

Input

Advertising