Optically Isolated Inputs and Outputs

Isolated (Current Sinking) Inputs

Number of channels ............................... 13

Input voltage range................................. 0 V to 30 V

Input ON voltage ............................ 3.5 V to 30 V
Input OFF voltage ........................... 0 V to 2 V

Turn-on current ...................................... 7.1 mA, typical

14 mA, maximum

Maximum pulse rate............................... 100 kHz

Minimum pulse detected ........................ 10

µs

Reverse polarity protection .................... Yes, –30 V

Isolated (Current Sourcing) Outputs

Number of channels ............................... 4

On-state voltage range ........................... 5 V to 30 V, maximum

Maximum on-state voltage
drop from Viso................................ 1.2 V at 100 mA

Output current

5 V isopower ................................... 50 mA, maximum

24 V isopower ................................. 100 mA, maximum

30 V isopower ................................. 100 mA, maximum

Maximum pulse rate............................... 10 kHz (maximum load

resistance 100 k

Ω)

Minimum pulse generated...................... 100

µs

Reverse polarity protection .................... Yes