Figure 4-8. example connections, Typical system setup, Typical system setup -15 – National Instruments NI CVS-1450 Series User Manual

Page 63

Advertising
background image

Chapter 4

Digital I/O Functionality

© National Instruments Corporation

4-15

NI CVS-1450 Series User Manual

Figure 4-8. Example Connections

When connecting to TTL inputs on the CVS-1450 device, match the output
impedance of the transmitting device to the characteristic impedance of the
cable. For example, if the cable characteristic impedance is 118

Ω, make

R

s

equal to 118

Ω, as shown in Figure 4-8.

Typical System Setup

Digital I/O configuration varies depending on the number of cameras your
system setup requires. You can access the digital I/O through the 44-pin
DSUB connector or through the three SMB connectors.

The digital I/O capabilities of the SMB connectors on the CVS-1450 device
are ideal for typical single-camera applications. The SMB connectors are
labeled TRIG 0, TRIG 1, and TRIG 2.

TTL OUT(0)

Receiving

Equipment

TTL IN(0)

118

44-Pin

DSUB

3
2

16
17

62 k

Transmitting

Equipment

R

S

TRIG 1

75

TRIG 1

SMB

RG-179

Coaxial Cable

+5 V

CVS-1450 device

Receiving

Equipment