An example of using general-purpose outputs is driving a relay that turns
on an Inspection in Progress light for an operator to see while the inspection
sequence is running.

I/O for Fault Conditions

The CVS-1450 device recognizes the following fault conditions:

External shutdown, when Shutdown mode is enabled

Watchdog timer expiration

Overheat

The behavior of the CVS-1450 device in the event of a fault condition is
dependent on configuration settings of the SAFE MODE DIP switch and
the software-enabled Shutdown mode. Table 4-4 summarizes how user
configuration affects the behavior of the CVS-1450 device in the event of a
fault condition. To resume operation, address the fault condition and reset
the CVS-1450 device. The following sections describe each fault condition.

Table 4-4. Configuration Settings and Effects

Fault

Condition

Configuration Settings

Configuration Effects

Safe Mode

DIP

Shutdown

Enabled

Processing Halts

Outputs Change to

User-Defined States

External
Shutdown

On

N/A

N/A

No

Off

On

Yes

Yes

Off

Off

No

No

Watchdog

On

N/A

N/A

No

Off

On

Yes

Yes

Off

Off

Yes

No

Overheat

On

N/A

Yes

No

Off

On

Yes

Yes

Off

Off

Yes

No