Appendix A

Troubleshooting

© National Instruments Corporation

A-5

NI CVS-1450 Series User Manual

POWER OK LED Is Not Lit When the CVS-1450 Device
is Powered On

If the power supply is properly connected to the CVS-1450 device, but the
POWER OK LED does not light up, check that the power supply is
24 VDC ±10% and within the specifications outlined in Appendix B,

Specifications

. Using a power supply that is not within these specifications

might result in an unresponsive or unstable system and could damage the
CVS-1450 device.

Table A-1. STATUS LED Flashes and Corresponding Error Conditions

Number

of Flashes

Error Condition

0 (stays lit)

The CVS-1450 device has detected an internal error.
Contact National Instruments for assistance.

1

The CVS-1450 device is unconfigured.

2

The CVS-1450 device has detected an error in its
software. This usually occurs when an attempt to
upgrade the firmware is interrupted. Repeat the
firmware upgrade process.

3

The CVS-1450 device is in Safe mode.

4 (or more)

The CVS-1450 device has detected an unrecoverable
error. Contact National Instruments for assistance.