Chapter 2

Parts Locator and Wiring Guide

SCB-68 Shielded Connector Block User Manual

2-4

ni.com

Table 2-1. Switch Configurations and Affected Signals

Switch Setting

Applicable Signals

Direct feedthrough, with temperature sensor disabled and
accessory power disabled

Analog input, analog output,
digital I/O, and timing I/O

Temperature sensor disabled, and accessory power enabled

2

Note: This configuration is the factory-default configuration.

Analog input
and analog output

1

S1

S2

S5 S4 S3

Signal Conditioning

Circuitry Power (Off)

Temperature Sensor

S1

S2

S5 S4 S3

Temperature Sensor

Signal Conditioning

Circuitry Power (On)