Specifications

SCB-68 Shielded Connector Block User Manual

A-2

ni.com

Voltage rating .........................................250 V

Nominal resistance .................................0.195

Physical

Box dimensions (including box feet)......19.5 by 15.2 by 4.5 cm

(7.7 by 6.0 by 1.8 in.)

I/O connectors.........................................One 68-pin male SCSI connector

Screw terminals ......................................68

Wire gauge

..............................................≤26 AWG

Resistor sockets ......................................0.032 to 0.038 in. (in diameter)

Maximum Working Voltage

Maximum working voltage refers to the signal voltage plus the
common-mode voltage.

Channel-to-earth .....................................42 V

rms

, Installation Category II

Channel-to-channel.................................42 V

rms

, Installation Category II

Environmental

Operating temperature ............................0 to 70 °C

Storage temperature ................................–20 to 70 °C

Humidity .................................................5 to 90% RH, noncondensing

Maximum altitude...................................2000 meters

Pollution Degree (indoor use only) ........II