National Instruments SCB-68 User Manual

Page 28

Advertising
background image

Chapter 2

Parts Locator and Wiring Guide

© National Instruments Corporation

2-5

SCB-68 Shielded Connector Block User Manual

Single-ended temperature sensor, with accessory power enabled

2

Single-ended analog input

3

Differential temperature sensor, with accessory power enabled

2

Differential analog input

1

When accessory power is enabled, I/O pin 8 is fused and is intended to be connected to +5V. This setting is not

recommended for use with the NI 653X, NI 670X, or NI 660X. Refer to the device user manual at

ni.com/manuals

to

determine if the device supplies +5 V to I/O pin 8.

2

Only applies to the signal conditioning circuitry.

3

Except NI 61XX devices. Refer to the device user manual at

ni.com/manuals

to determine if the device supports

single-ended inputs.

Table 2-1. Switch Configurations and Affected Signals (Continued)

Switch Setting

Applicable Signals

S1

S2

S5 S4 S3

Signal Conditioning

Circuitry Power (On)

Temperature Sensor

S1

S2

S5 S4 S3

Signal Conditioning

Circuitry Power (On)

Temperature Sensor

Advertising