Figure 5-18. current-to-voltage electrical circuit, Selecting a resistor, Selecting a resistor -17 – National Instruments SCB-68 User Manual

Page 62

Advertising
background image

Chapter 5

Adding Components for Special Functions

© National Instruments Corporation

5-17

SCB-68 Shielded Connector Block User Manual

Figure 5-18. Current-to-Voltage Electrical Circuit

The application software must linearly convert voltage back to current.
Equation 5-8 demonstrates this conversion, where the resistor is the
denominator and V

in

is the input voltage into the DAQ device:

(5-8)

Selecting a Resistor

For best results when measuring current, you should choose a resistor that
has the following characteristics:

Low wattage of approximately 1/8 W

Precision of at least 5%

Temperature stability

Tolerance of 5%

232

Ω (suggested)

AXL package (suggested)

Carbon or metal film (suggested)

If you use the resistor described above, you can convert a 20 mA current to
4.64 V by setting the device range to either (–5 to +5 V) or (0 to 5 V).