Chapter E

Soldering and Desoldering on the SCB-68

SCB-68 Shielded Connector Block User Manual

E-2

ni.com

1.

Disconnect the 68-pin cable from the SCB-68 if it is connected.

2.

Remove the shielding screws on either side of the top cover with a
Phillips-head number 1 screwdriver. You can now open the box.

3.

Loosen the strain-relief screws with a Phillips-head number 2
screwdriver.

4.

Remove the signal wires from screw terminals.

5.

Remove the device-mount screws and the 68-pin connector screws.

6.

Tilt the SCB-68 up and pull it out.

To reinstall the SCB-68, reverse the order of the steps.

The SCB-68 ships with wire jumpers in the F and G positions, as
Figure 2-1,

SCB-68 Printed Circuit Diagram

, shows. You must remove

the wire jumpers to use the positions. Use a low-wattage soldering iron
(20 to 30 W) when soldering to the SCB-68.

To desolder on the SCB-68, vacuum-type tools work best. Be careful to
avoid damaging the component pads when desoldering. Use only
rosin-core electronic-grade solder, because acid-core solder damages the
printed-circuit device and components.