Parameter 10: line folding, Parameter 11: binary speed of local dte – Northern UTA220/UTA220k User Manual

Page 101

Advertising
background image

UTA220/UTA220k

12-25

D-Channel X.25

Parameter 10: Line Folding

Parameter 10 specifies the maximum number of displayable
ASCII characters the PAD can send as a single line to the local
DTE before a new line is begun. The displayable ASCII decimal
characters (32 - 126) are shown in Appendix F. When the
maximum character number is reached, the PAD inserts a PAD
format effecter (carriage return and line feed) into the data
stream being transmitted or echoed to the local DTE device. The
format effecter advances the local DTE device display to the
beginning of the next line to continue the display of the data. In
the event the local DTE device automatically inserts line folding
when the characters reach the right-most end of the device
display, parameter 10 should be set to 0. This parameter applies
to data, PAD command characters, and PAD service signals.

*default

Parameter 11: Binary Speed of Local DTE

Parameter 11 reflects the current speed of the local DTE, which
is set automatically when the terminal adapter receives an AT
command prefix while in the AT command mode. This is a
READ ONLY parameter. The speed indicated by parameter 11
is the same speed indicated by S61.

Note: The parameter 11 value for the DTE speed does not
correspond to the same value for S61 for the same DTE speed
(see S61).

Table 12-16: Line Folding

Value

Description

0

No line folding *

1 to 255

Number of displayable ASCII characters per line

Table 12-17: DTE Binary Speed

Value

Description

2

300 bits / sec

3

1200 bits / sec

12

2400 bits / sec

13

4800 bits / sec

14

9600 bits / sec

15

19200 bits / sec

16

38400 bits / sec