Common apparent problems, Parameter 1 changed, Parameter 2 changed – Northern UTA220/UTA220k User Manual

Page 81: Parameter 5 changed, Parameter 6 changed, Parameter 20 changed, Pad command set, Pad command format

Advertising
background image

UTA220/UTA220k

12-5

D-Channel X.25

COMMON APPARENT PROBLEMS

During a session the X.25 network or remote PAD can alter
the current values of the X.3 parameters resulting in common
apparent problems.

Parameter 1 Changed

PAD recall using the character DLE (Ctrl P) is no longer
possible.

Parameter 2 Changed

Characters are no longer echoed when in the PAD command
mode.

Parameter 5 Changed

Flow control characters are sent to the DTE by the PAD during
the PAD command mode.

Parameter 6 Changed

The PAD prompt no longer appears when in the PAD
command mode.

Parameter 20 Changed

Editing characters are echoed.

PAD COMMAND SET

The X.25 PAD serves as an asynchronous interface through
which the X.25 protocol and PAD operation can be controlled.
PAD commands are specified in X.28 by CCITT which allow
for communication directly with the PAD. Some of the X.28
PAD commands control the X.25 protocol operation such as
call setup, call clearing, etc. The rest of the PAD commands
provide access to the X.3 PAD parameters for PAD operation
control (refer to the X.3 Parameters and Values section).

PAD Command Format

The format of each PAD command is described in the section
below. The PAD accepts either upper or lowercase characters
for the PAD command characters. Any spaces inserted in the
PAD command are ignored except for spaces in the call user
data of the PAD select command (see PAD select command).
A PAD command line can contain up to 128 characters.
Multiple PAD commands are not permitted on a command
line.

Advertising