AT Command Set

%B12=

Transmit Through Input
Class

0

Use network default

<default>
1

Reserved

2

Reserved

3

75

4

110

5

300

6

600

7

1200

8

2400

9

4800

10

9600

11

19200

12

48000

13

64000

14

Reserved

15

Reserved

%B13=

Network User ID

Range: 0-16 characters

default (null string)

%B14=

RPOA

Range: 0-16 characters

default (null string)

%B15=

Called Line Address
Modification Code (Caller,
Read Only)

0

Call not redirected

<default>

1

Called station was busy

7

Call distribution within a hunt
group

9

Called station was out of or-

der
15

Systematic call redirection by
called station

Not saved in non-volatile. Initialized
to factory defaults before each virtual
call.

%B16=

Called Redirection
Notification Code (Called,
Read Only)

0

Call not redirected

<default>

1

Called station was busy

9

Called station was out of or-

der
15

Systematic call redirection by
called station

Not saved in non-volatile. Initialized
to factory defaults before each virtual
call.

%B17=

Intended Call Address

Range: 0-15 digits

default (null

string)

%B18=

User Data

Range: 0-12 characters

default (null string)

Table C-1: UTA 220 AT Command Set (Continued)

Command

Description

Value

*Note: "by port" indicates that these switch parameters are associated with a
particular port. However, this does not exclude ports from sharing the same
SPID or TEI.+