Step lcd screen display action, Table 3-4: programming steps (continued) – Northern UTA220/UTA220k User Manual

Page 32

Advertising
background image

3-8

UTA220/UTA220k

Getting Started

14

D-CHANNEL PROV
OPTIONS?

Press NO.

15

D-CHANNEL
LAPD OPTIONS?

Press YES.

16

CURRENT PORT = 1
CHANGE?

Press NO.

17

P1:X.25 TEI=DIS
CHANGE?

If D-channel X.25 is desired, follow the selections described in Step 18 for entering
a TEI value. For AT&T 5ESS switches, this setting is normally "AUTO". For NT
DMS-100 and NT-1 switches, a manual TEI (0-63) value is normally required. If
D-Channel X.25 is not desired, press NO.

18

P1: DATA TEI = AUTO.
CHANGE?

There are three classes of possible DATA TEI value settings: "AUTO", "DIS", and
0-63. Use one of the setup cases below that matches your TEI value.

"AUTO"
TEI:

Press NO to advance to the next menu. The "AUTO"
value is used to select a dynamically assigned TEI.
"AUTO" is the factory default and should be correct
in most situations.

"DIS"
TEI:

Press YES to scroll through the supported TEI
values until "DIS" is displayed. Press NO to advance
to the next menu.

0-63
(UTA220k):

Press YES twice "00" is displayed. Press the keypad
number keys until the entire number has been keyed
in. If the number is one digit long, press the
appropriate number key, then press ENTER.

0-63
(UTA220):

Press YES until the first digit of the value is displayed
then press NO to accept the digit and advance to
the next digit. Continue to do this until the entire
number has been keyed in. If the number is one digit
long, enter the first digit, then press YES until the
character "_" is displayed to the right of the digit.
Press NO to enter the TEI number.

Note: If only one circuit-switched call at a time is necessary and the call will always
be placed to or from the same Directory Number, then only one of the TEIs should
be enabled and the other disabled.

19

P1:_____________
SPID. CHANGE?

- The SPID only needs to be configured if the TEI is not disabled.
- Enter the SPID string in the same manner as the TEI. The SPID value can be up
to 20 digits in length.

20

P1:_____________
DN. CHANGE?

- The Directory Number (DN) only needs to be configured if the TEI is not disabled.
The DN is optional for AT&T 5ESS switch types.
- Enter the DN string in the same manner as the TEIs and SPIDs. Like the SPID
strings, the DN strings can be up to 20 digits in length.

21

CURRENT PORT = 1
CHANGE?

Press 2.

22

P2: X.25 TEI=DIS
CHANGE?

Press NO

23

P2: DATA TEI = AUTO
CHANGE?

Same as Step 18.

24

P2:_____________
SPID. CHANGE?

- The SPID only needs to be configured if the TEI is not disabled.
- Enter the SPID string in the same manner as the TEI. The SPID value can be up
to 20 digits in length.

25

P2:_____________
DN. CHANGE?

- The Directory Number (DN) only needs to be configured if the TEI is not disabled.
The DN is optional for AT&T 5ESS switch types.
- Enter the DN string in the same manner as the TEIs and SPIDs. Like the SPID
strings, the DN strings can be up to 20 digits in length.

26

If you have a two-port unit, then continue with STEP 37.

Table 3-4: Programming Steps (Continued)

STEP

LCD SCREEN

DISPLAY

ACTION

Advertising