Northern UTA220/UTA220k User Manual

Page 94

Advertising
background image

12-18

UTA220/UTA220k

D-Channel X.25

To save the current X.3 parameter configuration to nonvolatile
memory, escape to command mode and enter AT&W
(see Escaping to AT Command Mode in Establishing an X.25
Session). Entering AT&W saves the port and current session
configuration as well as the X.3 parameters. The factory X.3
configuration can be restored by entering AT&F. This
command also restores port and current session configuration.

CCITT specifies two standard profiles for the X.3 parameter
set. The transparent profile is recommended for applications
such as file transfers. The transparent profile essentially
disables most of the PAD features so that the file can be
transferred completely unaltered (no padding, line feed
insertion, flow control characters, or service signal messages
when transmitted to the DTE). The simple profile is an
alternative configuration to the TA’ s default configuration for
simple interactive terminal applications. Table 12-6 lists the
X.3 parameters and the values supported by the TA.

18

Line display

18

Ctrl R (12H of ASCII Character
Table) is the line display
character

19

Editing PAD
service signals

2

Editing PAD service signals is
generated for display terminals

20

Echo mask

64

No echo of edit characters

21

Parity treatment

0

No parity check or generation

22

Page wait

0

Disabled

Table 12-6:

CCITT X.3 Parameter Profiles

Parameter

Description

Transparent

Profile

Simple

Profile

1

PAD recall using a character

0

1

2

Echo

0

1

3

Data forwarding character selection

0

126

4

Idle timer delay selection

1

0

5

Ancillary device control

0

1

6

Control of PAD service and command
signals

0

1

7

Action of PAD on break from DTE

0

0

8

Discard output

0

0

9

Padding after carriage return

0

0

Table 12-5:

Default X.3 Parameters

(Continued)