National Instruments Low-Cost Multifunction I/O Board for ISA Lab-PC+ User Manual

Page 45

Advertising
background image

Signal Connections

Chapter 3

Lab-PC+ User Manual

3-14

© National Instruments Corporation

are connected to the digital lines PC<0..7> for digital I/O Port C. Pin 13, DGND, is the digital
ground pin for all three digital I/O ports.

The following specifications and ratings apply to the digital I/O lines.

Absolute maximum voltage input rating: +5.5 V with respect to DGND

-0.5 V with respect to DGND

Logical Inputs and Outputs

Digital I/O lines:

Minimum

Maximum

Input logic low voltage

-0.3 V

0.8 V

Input logic high voltage

2.2 V

5.3 V

Output logic low voltage

-

0.4 V

(at output current = 2.5 mA)

Output logic high voltage

3.7 V

-

(at output current = -2.5 mA)

Darlington drive current

±

2.5 mA

±

4.0 mA

(R

EXT

= 700

, V

EXT

= 1.7 V)

Figure 3-8 illustrates signal connections for three typical digital I/O applications.

Advertising