Mode 2 Bidirectional Timing

The timing specifications for bidirectional transfers in Mode 2 are as follows:

T1

T6

T7

T3

T4

T10

T2

T5

T8

T9

WR *

OBF *

INTR

ACK *

STB *

IBF

RD *

DATA

Name

Description

Minimum

Maximum

T1

WR* = 1 to OBF* = 0

650

T2

Data before STB* = 1

0

T3

STB* pulse width

500

T4

STB* = 0 to IBF = 1

300

T5

Data after STB* = 1

180

T6

ACK* = 0 to OBF = 1

350

T7

ACK* pulse width

300

T8

ACK* = 0 to output

300

T9

ACK* = 1 to output float

20

250

T10

RD* = 1 to IBF = 0

300

All timing values are in nanoseconds.