Mode 1 Input Timing
The timing specifications for an input transfer in Mode 1 are as follows:
DATA
RD *
INTR
IBF
STB *
T1
T2
T4
T7
T6
T3
T5
Name
Description
Minimum
Maximum
T1
STB* pulse width
500
–
T2
STB* = 0 to IBF = 1
–
300
T3
Data before STB* = 1
0
–
T4
STB* = 1 to INTR = 1
–
300
T5
Data after STB* = 1
180
–
T6
RD* = 0 to INTR = 0
–
400
T7
RD* = 1 to IBF = 0
–
300
All timing values are in nanoseconds.