Smartcontroller operation, 1 smartcontroller cs connectors and indicators, Figure 3-1 – Nortech Systems Adept RS-232/TERM User Manual

Page 37: Smartcontroller cs, Table 3-1, Smartcontroller leds, Chapter 3

Advertising
background image

Adept SmartController User’s Guide, Rev. E

37

SmartController Operation

3

3.1

SmartController CS Connectors and Indicators

Figure 3-1. SmartController CS

All the connectors on the SmartController use standard density spacing, D-subminiature
connectors. For customization purposes, the user needs to provide connectors of the
appropriate gender and pin count or use optional Adept cables.

NOTE: The SmartController CX has all of the connectors and indicators
described in this section for the SmartController CS, plus additional ones
covered in

Section 3.2 on page 40

.

1. Top Three Status LEDs

The top three two-color LEDs indicate diagnostic test, power control, and communication
status.

During system bootup, the red OK/SF and HPE/ES LEDs are lit and the red LAN/HD LED
blinks. After system bootup, the OK/SF LED should show green. If the HPE/ES LED shows
red, the E-Stop circuit is open. During CompactFlash reads and writes, the LAN/HD LED
pulses red. When the controller is active on an Ethernet network, the LAN/HD LED pulses
green.

Table 3-1. SmartController LEDs

LED

Green Indicates

Red Indicates

OK/SF

System OK

System Fault

HPE/ES

High Power Enabled

E-Stop Open

LAN/HD

Ethernet Access

Read/Write from
CompactFlash

1 2 3

RS-422/485

XUSR

XSYS

SF

XMCP

1.1

SmartController CS

LAN

HPE

OFF

24V

5A

ON

RS-232/TERM

XFP

HD

ES

XDIO

Eth 10/100

*S/N 1000-XXXXX*

SW1

Device Net

SmartServo

XDC1 XDC2

- +

- +

1 2 3 4

OK

R

1.2

Advertising