Installing Camera Cables

Figure 4-3 on page 73

shows the installation of a typical four-camera RS-170 breakout

cable and the associated hardware in a SmartController CX system. See the

AdeptVision

User’s Guide

for information on mounting cameras and strobes in your system.

Connecting the Cables to the RS-170 Standard Camera

This section describes the steps for connecting the cables between the sAVI board and the
RS-170 Cameras.

1. Turn off the SmartController CX.

2. Connect the camera to a 10m camera cable.

3. Connect the 10m camera cable to the appropriate connection on the camera

breakout cable.

4. Connect the power supply and strobe lamps through the 9 pin D-sub connector

(see

Figure 4-2 on page 71

and

Table 4-2 on page 76

for pin assignments).

5. Connect the camera breakout cable to the Camera connector on the

SmartController CX.

CAUTION:

Turn off the controller before installing or

removing a camera or cable. Failure to do this may
damage the sAVI board.

CAUTION:

When using the four-camera breakout cable,

you must provide 12 VDC power at sufficient current for
the type and quantity of cameras you are using. See the
documentation supplied with your cameras for
information on current requirements.