Nortech Systems Adept RS-232/TERM User Manual

Page 100

Advertising
background image

Appendix A - sDIO Module

100

Adept SmartController User’s Guide, Rev. E

3. Select option 2.

2 - Edit system configuration

Then, press ENTER to continue.

4. Select either option 5 or option 6:

5 - Change DIGITAL_INPUT configuration

or

6 - Change DIGITAL_OUTPUT configuration

Then, press ENTER to continue.

5. The program will step you through the process of adding a new statement to

assign the appropriate I/O signals to a block, and then to a byte (1 to 4) within a
block. With the sDIO, the first 8 input channels are mapped to byte 1, the second 8
input channels to byte 2, and so on. See

sDIO Signal Mapping Example 1

. Using

this process, you must assign groups of signal numbers to bytes 1 to 4 for each
block. See the

sDIO Signal Mapping Example 2

for the input settings of a system

with two sDIO modules. When you are done editing the I/O choose not to add a
new statement.

6. Save the changes, if you are satisfied with your choices.

7. Continue to select 0 to return through the higher menus. Select 0 once more to exit

to the system monitor.

8. Disconnect your AdeptWindowsPC or serial communication session to the

SmartController.

9. Cycle the 24VDC input power to the sDIO.

10. Cycle the 24VDC input power to the SmartController.

11. Reconnect your AdeptWindowsPC or serial communication session to the

SmartController.

Advertising
This manual is related to the following products: