Chapter 3 - SmartController Operation

50

Adept SmartController User’s Guide, Rev. E

10,23

MANUAL/AUTO indication CH 2

Contacts are closed in
AUTOMATIC mode

11,12,

13,24,25

No connection

Table 3-8. Contacts Provided by the XFP Connector

Pin

Pairs

Description

Comments

Voltage-Free Contacts Provided by Customer

1,9

Front Panel E-Stop CH 1

N/C contacts

2,10

Front Panel E-Stop CH 2

N/C contacts

3,11

Remote MANUAL/AUTOMATIC switch CH 1.
MANUAL = Open AUTOMATIC = Closed

4,12

Remote MANUAL/AUTOMATIC switch CH 2.
MANUAL = Open AUTOMATIC = Closed

6,14

Remote High Power on/off momentary PB

Used to enable High Power

Nonvoltage-Free Contacts

5,13

Adept Supplied 5 VDC and GND for High Power
On/Off Switch Lamp

Use with Remote High
Power On/Off switch above.

7,15

SmartController system 5V power on LED, 5V, 20mA

8

No connection

See

Figure 3-6 on page 54

for a schematic diagram of the Adept Front Panel.

Table 3-7. Contacts Provided by the XUSR Connector (Continued)

Pin

Pairs

Description

Comments

Shorted if

NOT Used

XUSR

Pin 1

Pin 13

Pin 14

Pin 25

Pin 1

Pin 8

Pin 9

Pin 15