Connecting Customer-Supplied Safety and Power Control Equipment

Adept SmartController User’s Guide, Rev. E

49

3.7

Connecting Customer-Supplied Safety and Power Control
Equipment

Connecting Equipment to the System

The connection of the customer-supplied safety and power control equipment to the
system is done through the XUSR and XFP connectors on the SmartController. The XUSR
connector (25-pin) and XFP (15-pin) connector are both female D-sub connectors located
on the front panel of the SmartController. Refer to

Table 3-7

for the XUSR pin-out

explanations. Refer to

Table 3-8 on page 50

for the XFP pin-out explanations. See

Figure

3-5 on page 53

for the XUSR wiring diagram.

Table 3-7. Contacts Provided by the XUSR Connector

Pin

Pairs

Description

Comments

Shorted if

NOT Used

Voltage-Free Contacts Provided by Customer

1, 14

User E-Stop CH 1 (mushroom PB,
safety gates, etc.).

N/C contacts

Yes

2,15

User E-Stop CH 2 (same as pins 1
and 14).

N/C contacts

Yes

3,16

Line E-Stop (used for other robot or
assembly line E-Stop
interconnection. Does not affect
E-Stop indication (pins 7, 20.))

N/C contacts

Yes

4,17

Line E-Stop (Same as pins 3 and 16.
See above comment.)

N/C contacts

Yes

5,18

Muted safety gate CH 1 (causes
E-stop in AUTOMATIC mode only).

N/C contacts

Yes

6,19

Muted Safety Gate CH 2 (same as
pins 5 and 18).

N/C contacts

Yes

Voltage-Free Contacts provided by Adept

7,20

E-Stop indication CH 1.

Contacts are closed when
Front Panel, MCP, and
customer E-Stops are not
tripped

8,21

E-stop indication CH 2 (same as pins
7 and 20.

Contacts are closed when
Front Panel, MCP, and
customer E-stops are not
tripped

9,22

MANUAL/AUTO indication CH 1

Contacts are closed in
AUTOMATIC mode