Table Mounting the sDIO

To table mount the sDIO, install two brackets on each side near the bottom of the unit. Use
the screws from the accessories kit; see

Figure A-4

.

Figure A-4. Table Mounting the sDIO

Stack Mounting

See the

“Stacking Components” section on page 28

for information on stack mounting

the sDIO and SmartController.

A.2

Installing the sDIO

The following procedure details the steps required to successfully install the sDIO.

To install the sDIO module:

1. Remove the sDIO module from its box and set it up near the robot or mount it as

described in

“Mounting the sDIO” on page 93

.

2. Ensure that the 24VDC input power to the SmartController is disengaged.

3. Connect a 24VDC cable from the XDC2 port on the SmartController to the XDC1

port on the sDIO. Continue to daisy-chain the input power from each sDIO to the
next. See

“Connecting Power” on page 30

for cabling requirements.

NOTE: European installations must be in accordance with the EN60204
standard.

R 3.6