National Instruments Corporation

Analog Output Signal Connections

PCI-6024E and PCI-6025E

The analog output signals are DAC0OUT, DAC1OUT, and AOGND.
DAC0OUT and DAC1OUT are not available on the PCI-6023E.

DAC0OUT is the voltage output signal for analog output channel 0.
DAC1OUT is the voltage output signal for analog output channel 1.

AOGND is the ground reference signal for both analog output channels and
the external reference signal.

Figure 4-9 shows how to make analog output connections to your board.

Figure 4-9. Analog Output Connections

+

-

+

-

Channel 0

Channel 1

Load

Load

VOUT 0

VOUT 1

DAC1OUT

AOGND

DAC0OUT

Analog Output Channels