PRODUCT PREVIEW

7.7.3

PLL1 Controller Register Descriptions

TMS320C6454

Fixed-Point Digital Signal Processor

SPRS311A – APRIL 2006 – REVISED DECEMBER 2006

This section provides a description of the PLL1 controller registers. For details on the operation of the PLL
controller module, see the TMS320C645x DSP Software-Programmable Phase-Locked Loop (PLL)
Controller User's Guide
(literature number

SPRUE56

).

NOTE: The PLL1 controller registers can only be accessed using the CPU or the emulator.

Not all of the registers documented in the TMS320C645x DSP Software-Programmable Phase-Locked
Loop (PLL) Controller User's Guide
(literature number

SPRUE56

) are supported on the TMS320C6454.

Only those registers documented in this section are supported. Furthermore, only the bits within the
registers described here are supported. You should not write to any reserved memory location or change
the value of reserved bits.

7.7.3.1 PLL1 Control Register

The PLL control register (PLLCTL) is shown in

Figure 7-11

and described in

Table 7-19

.

31

16

Reserved

R-0

15

8

7

6

5

4

3

2

1

0

PLL

Reserved

Rsvd

Rsvd

Reserved

PLLRST

Rsvd

PLLEN

PWRDN

R-0

R/W-0

R-1

R/W-0

R/W-1

R-0

R/W-0

R/W-0

LEGEND: R/W = Read/Write; R = Read only; -n = value after reset

Figure 7-11. PLL1 Control Register (PLLCTL) [Hex Address: 029A 0100]

Table 7-19. PLL1 Control Register (PLLCTL) Field Descriptions

Bit

Field

Value

Description

31:8

Reserved

Reserved. The reserved bit location is always read as 0. A value written to this field has no effect.

7

Reserved

Reserved. Writes to this register must keep this bit as 0.

6

Reserved

Reserved. The reserved bit location is always read as 1. A value written to this field has no effect.

5:4

Reserved

Reserved. Writes to this register must keep this bit as 0.

3

PLLRST

PLL reset bit

0

PLL reset is released

1

PLL reset is asserted

2

Reserved

Reserved. The reserved bit location is always read as 0. A value written to this field has no effect.

1

PLLPWRDN

PLL power-down mode select bit

0

PLL is operational

1

PLL is placed in power-down state, i.e., all analog circuitry in the PLL is turned-off

0

PLLEN

PLL enable bit

0

Bypass mode. Divider PREDIV and PLL are bypassed. All the system clocks (SYSCLKn) are
divided down directly from input reference clock.

1

PLL mode. Divider PREDIV and PLL are not bypassed. PLL output path is enabled. All the system
clocks (SYSCLKn) are divided down from PLL output.