3 i2c electrical data/timing, Product preview – Texas Instruments TMS320C6454 User Manual

Page 163

Advertising
background image

www.ti.com

PRODUCT PREVIEW

7.11.3 I2C Electrical Data/Timing

TMS320C6454

Fixed-Point Digital Signal Processor

SPRS311A – APRIL 2006 – REVISED DECEMBER 2006

7.11.3.1

Inter-Integrated Circuits (I2C) Timing

Table 7-52. Timing Requirements for I2C Timings

(1)

(see

Figure 7-42

)

-720
-850

-1000

NO.

UNIT

STANDARD MODE

FAST MODE

MIN

MAX

MIN

MAX

1

t

c(SCL)

Cycle time, SCL

10

2.5

µ

s

Setup time, SCL high before SDA low (for a

2

t

su(SCLH-SDAL)

4.7

0.6

µ

s

repeated START condition)

Hold time, SCL low after SDA low (for a

3

t

h(SCLL-SDAL)

4

0.6

µ

s

START and a repeated START condition)

4

t

w(SCLL)

Pulse duration, SCL low

4.7

1.3

µ

s

5

t

w(SCLH)

Pulse duration, SCL high

4

0.6

µ

s

6

t

su(SDAV-SDLH)

Setup time, SDA valid before SCL high

250

100

(2)

ns

Hold time, SDA valid after SCL low (For I

2

C

7

t

h(SDA-SDLL)

0

(3)

0

(3)

0.9

(4)

µ

s

bus™ devices)

Pulse duration, SDA high between STOP and

8

t

w(SDAH)

START

4.7

1.3

µ

s

conditions

9

t

r(SDA)

Rise time, SDA

1000

20 + 0.1C

b

(5)

300

ns

10

t

r(SCL)

Rise time, SCL

1000

20 + 0.1C

b

(5)

300

ns

11

t

f(SDA)

Fall time, SDA

300

20 + 0.1C

b

(5)

300

ns

12

t

f(SCL)

Fall time, SCL

300

20 + 0.1C

b

(5)

300

ns

Setup time, SCL high before SDA high (for

13

t

su(SCLH-SDAH)

4

0.6

µ

s

STOP condition)

14

t

w(SP)

Pulse duration, spike (must be suppressed)

0

50

ns

15

C

b

(5)

Capacitive load for each bus line

400

400

pF

(1)

The I2C pins SDA and SCL do not feature fail-safe I/O buffers. These pins could potentially draw current when the device is powered
down.

(2)

A Fast-mode I

2

C-bus™ device can be used in a Standard-mode I

2

C-bus™ system, but the requirement t

su(SDA-SCLH)

250 ns must then

be met. This will automatically be the case if the device does not stretch the LOW period of the SCL signal. If such a device does stretch
the LOW period of the SCL signal, it must output the next data bit to the SDA line t

r

max + t

su(SDA-SCLH)

= 1000 + 250 = 1250 ns

(according to the Standard-mode I

2

C-Bus Specification) before the SCL line is released.

(3)

A device must internally provide a hold time of at least 300 ns for the SDA signal (referred to the V

IHmin

of the SCL signal) to bridge the

undefined region of the falling edge of SCL.

(4)

The maximum t

h(SDA-SCLL)

has only to be met if the device does not stretch the low period [t

w(SCLL)

] of the SCL signal.

(5)

C

b

= total capacitance of one bus line in pF. If mixed with HS-mode devices, faster fall-times are allowed.

Submit Documentation Feedback

C64x+ Peripheral Information and Electrical Specifications

163