3 timers electrical data/timing, Product preview – Texas Instruments TMS320C6454 User Manual
Page 206

www.ti.com
PRODUCT PREVIEW
7.15.3 Timers Electrical Data/Timing
TINPLx
TOUTLx
4
3
2
1
TMS320C6454
Fixed-Point Digital Signal Processor
SPRS311A – APRIL 2006 – REVISED DECEMBER 2006
Table 7-94. Timing Requirements for Timer Inputs
(1)
(see
-720
-850
NO.
UNIT
-1000
MIN
MAX
1
t
w(TINPH)
Pulse duration, TINPLx high
12P
ns
2
t
w(TINPL)
Pulse duration, TINPLx low
12P
ns
(1)
P = 1/CPU clock frequency in ns. For example, when running parts at 1000 MHz, use P = 1 ns.
Table 7-95. Switching Characteristics Over Recommended Operating Conditions for Timer Outputs
(1)
(see
-720
-850
NO.
PARAMETER
UNIT
-1000
MIN
MAX
3
t
w(TOUTH)
Pulse duration, TOUTLx high
12P – 3
ns
4
t
w(TOUTL)
Pulse duration, TOUTLx low
12P – 3
ns
(1)
P = 1/CPU clock frequency in ns. For example, when running parts at 1000 MHz, use P = 1 ns.
Figure 7-73. Timer Timing
206