5. PROGRAMMING OPERATIONS

EO1-11138

5-35

5.4 How to Access a Program Item

* SET * 02-06-1999 12:34
PROGRAMMING TARE SCALE

01 0.001b
02 0.001b
03 0.001b
04 0.001b
05 0.001b
06 0.001b
07 0.001b
08 0.001b

Please input item No.
0.00

Pg up Pg dw Enter

Tare Table and General Unit Weight Setting (Submode 26)

In the PLU Table Programming operation (Submode 4), some of Scale-compulsory PLUs may be set with a
Tare Table No. The actual tare weight is set to each Tare Table here. Also, the General Unit Weight is set
here so that the Unit Weight may be effective to scale items entered through departments or PLUs without any
Individual Unit Weight designation.

CONDITION

Any time outside a sale

When you enter 26 and depress the [X] key,

the screen shown below will appear.

OPERATION

Mode Lock: SET

26 [X]

|Tare Table No.| [ST]

|Tare Weight| [#]

1 to 9

*

0 to 999 (Unit: 1/100
LB or gram. Example:
enter 13 for 0.13 LB.)

. . .

Repeat for other tables.

* (For sequentially programming tables, the

Table No. specification can be skipped.)

LB Unit

Kg Unit

1:

1 LB

1 Kg

2

2 LB

2 Kg

3

3 LB

3 Kg

4

4 LB

4 Kg

5

5 LB

5 Kg

6

6 LB

6 Kg

7

7 LB

7 Kg

8

8 LB

8 Kg

9

9 LB

9 Kg

10

1/2 LB

100 g

11

1/4 LB

Not applicable

10 [ST]

|General Unit Weight Code| [#]

[AT/TL]

Only to set
the General
Unit Weight

**

1 to 11

** Only to set the

Tare Weight

ex.) To set the following.

Journal Print

Tare Table No. 1 with Tare Weight 0.13 LB

General Weight 2 LB (Code 2).

Mode Lock: SET
Enter 26, depress [X].
1 [ST] 13 [#] 10 [ST] 2 [#] [AT/TL]

P26 TARE SCALE
#01 0.131b
#10 21b
0042 15:26TM

NOTE:

The initial value for the General Unit Weight is set to Code 1 (1LB or 1Kg).